Troubleshooting
When you hit a problem, first check it against the symptoms in this chapter. If none match, contact us via "Getting help" at the end.
1. No video (Live keeps buffering)
| Possible cause | How to verify | Fix |
|---|---|---|
| Wrong RTSP URL | Try the same URL in VLC | Change the URL and re-save; when ONVIF auto-discovery returns a wrong address, switch to manual RTSP |
| Wrong credentials | The web admin reports auth failure | Go to camera details and change the password; the ONVIF password ≠ the RTSP password |
| Low-latency channel blocked | DevTools → Network shows a connection error | Open UDP 23515 in the firewall; if you can't, it auto-switches to the stable channel (2–4s latency) |
| Camera uses a proprietary protocol (Tapo / Xiaomi) | The camera brand isn't in the Cameras list | Use a go2rtc bridge |
| The streaming gateway didn't start | docker logs yunkan for startup errors | Usually a port conflict; try restarting the container |
2. Playback is black / the progress bar won't move
- Recording isn't on: Camera details → Recording settings → enable
- Disk full:
df -hto check the partition holding data, then delete old recordings or shorten the retention days - Corrupted recording segment: find the matching
data/recordings/<id>/<date>/<HH-MM-SS>.mp4and try playing it in VLC; a corrupted segment loses at most 5 minutes - Wrong time: if the server and camera time zones are out of sync, the playback timeline is off by 8 hours; check with
timedatectl
3. AI detection isn't working
| Symptom | Cause | Fix |
|---|---|---|
| The events page stays empty | The global detection toggle is off | Settings → Detection → enable |
| One camera doesn't detect | That camera has a "detection failed" status | Camera details → "Clear detection error" |
| GPU at 0 usage | Wrong image variant (running the cpu image on a GPU box) | Pull the matching variant image and restart |
| Faces always "Stranger" | This person was never added / the threshold is too strict | Add the face / lower the face similarity threshold |
| Many false fall alerts | The descent-velocity threshold is too low | Raise the fall descent-velocity threshold a bit |
4. The container keeps restarting
Use docker logs --tail 200 yunkan to see the last output. Common errors:
- Missing config: in wizard mode but the health check fails → just finish the /setup wizard in the browser
- Port in use:
ss -tnlp | grep 23406, then stop the conflicting service or change the port - Hardware files not mounted: the bind-mount didn't include
/etc/machine-id, so license validation crashes; add it per Installation - Unsupported architecture: SkyView publishes x86_64 and RK3588 (arm64) images only; other ARM machines can't run it (
uname -mshould outputx86_64; if it printsaarch64, only RK3588 boards work — see RK3588 Deployment)
5. Uploading to 115 fails
- Login expired (about 30 days): Settings → 115 → re-scan to log in
- VIP expired: very large files need 115 VIP's instant-upload channel; non-VIP uses a rate-limited channel
- Target folder deleted: recreate the folder in 115, then return to SkyView and re-select it
- Unstable network: upload tasks have built-in retries; check
docker logs yunkanfor the specific error
6. Automation doesn't trigger
- Quiet hours: Settings → Notifications → Quiet hours, check whether you're currently within that window
- Cooldown: repeated events within 30 seconds are swallowed; lower the cooldown or use a different event type
- Condition mismatch: the rule added "recognized person = Zhang San" but it was actually recognized as "Stranger", so the rule won't trigger; relax the condition
- MQTT not connected: Settings → Integrations → MQTT to check the connection status, and verify the address / credentials
7. The wizard reappears after upgrading / data is gone
Jumping to /setup after an upgrade is almost always because the data directory wasn't mounted correctly — the container can't see the config file written last time, so it assumes a fresh install. Check:
docker inspect yunkan | grep -A 2 Mounts
# You should see Source: /home/.../data, Destination: /app/data
# If the path changed / isn't mounted, docker rm the container and mount it correctly on the next docker runNever go through the wizard again
8. Forgot the password and cannot log in
First, find your case:
| Situation | What to do |
|---|---|
| You know the password and just want to change it | Log in and go to Settings → Users |
| A family member forgot theirs | Ask an administrator to reset it in Settings → Users |
| The administrator forgot it and nobody can get in | Use the command below |
SkyView runs on your own machine, so there is no password-reset email. When the administrator is locked out, run the command below on the machine SkyView is installed on. Anyone who can use that machine already has full control of it anyway.
# See which accounts exist
docker exec -it yunkan skyview-reset-password --list
# Reset one account. You will be asked to type the new password twice (it is not shown on screen)
docker exec -it yunkan skyview-reset-password --user adminPassword rules
If that account was disabled, resetting the password alone still will not let it log in. Add --activate to re-enable it at the same time:
docker exec -it yunkan skyview-reset-password --user admin --activateIf your container is not named yunkan
yunkan is the default container name created by the one-line installer. If you installed from a NAS app store or as a Home Assistant add-on, the name may differ. Run docker ps to check, then replace yunkan in the commands above.Resetting a password does not sign anyone out
9. How to read logs
# Single-image deploy: all logs are mixed together
docker logs --tail 500 -f yunkan
# To see only detection-related:
docker logs yunkan 2>&1 | grep -i detection
# Multi-container deploy: each component is separate
docker compose logs -f api detectionGetting help
- Support ticket: Customer portal → My Orders → Open a ticket, attach the output of
docker logs --tail 200 yunkan, fastest follow-up - Email: support@yun-kan.com (reply within 24 hours)
- WeChat group: after purchase, the "My Orders" page in the customer portal has a group QR code (paid users only)
Was this page helpful?